Standard AC Motor (Round Shaft)

Overview
Technical Information
  • High durability: adopt high-strength die-cast aluminum alloy housing and carburized gears, hardness is up to HRC62.
  • Low noise: good design, precision manufacturing, noise below 65dB(A)
  • Maintenance-free: compact machine, gearbox lubricated with grease, maintenance-free for life.
  • Wide application: various models and installation methods are widely used in most industries.
  • Insulation grade: F grade, temperature resistance 155 ℃.
Power 6~250W
Phase number Single phase/three phase
Voltage 110V/220V/380V
(support customization)
Frequency 50/60Hz
Motor speed 1300~1600rpm
Features
Parameters
Directory
Product Features
  • 1
    Hight torque, high load-bearing capacity
  • 2
    Low noise, maintenance-free
  • 3
    High efficiency, low temperature rise
  • 4
    Wide power range, wide application
  • 5
    Customized for multiple industries
Performance Parameter

COMPACT AC GEAR MOTOR 60YS06WG/DV22_
1. Stand code 2. Name code 3. Power 4. Rotor shaft form Code 5. Voltage Code 6. Derived Code
60、70、80、90、100 YS: STANDARD MOTOR
YT: VARIABLE SPEED MOTOR
YB: ELECTROMAGNETIC BRAKE MOTOR
YF: VARIABLE SPEED ELECTROMAGNETIC BRAKE MOTOR
YR: DAMPING MOTOR
6W、15W、25W、40W、60W、90W、120W、140W、200W、250W G:GEAR SHAFT
D:ROUND SHAFT
V11:SINGLE PHASE 110V
V22:SINGLE PHASE 220V
Y22:THREE PHASE 220V
Y38:THREE PHASE 380V
X: LEAD (LINE LENGTH 300mm)
T:WITH THERMAL PROTECTOR
H:WITH TERMINAL BLOCK
FF:WITH ELECTRONIC FAN (LOW TEMPERATURE)


Performance Parameter

INSULATION RESISTANCE After running at rated settings under normal temperature and humidity, the insulation resistance between the winding and the motor shell measured with a DC 500V megger should be more than 100MΩ.
INSULATION VOLTAGE Afer running at rated setings under normal temperature and humidiy, apply 50Hz or 60Hz, 1.5KV between the winding and the shell for one minute, and the motor is normal.
TEMPERATURE RlISE When running at rated setings with gearbox or equivalent heat radiating plate instaed,the temperature rise of the winding measured in resistance method is 75K or less.
INSULATION CLASS F(155°C)
OVERHEATING PROTECTION DEVICE With built-in thermal protection device (automatic reset type) Working temperature: 120±5℃. Reset temperature: 82±15℃ (this function needs to be customized)
AMBIENT TEMPERATURE -10°C~+40°C(no freezing)
AMBIENT HUMIDITY Below 85%(no condensation)


Performance Parameter

Maximum output power
(W)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Speed range
(r/min)
Start torque
(mN·m)
Rated torque (mN·m) 1200r/min
25 THREE PHASE 220V 50Hz 0.25 90 - 1300 250 195
THREE PHASE 380V 60Hz 0.14 90 - 1600 205 160
40 THREE PHASE 220V 50Hz 0.35 90 - 1300 403 310
THREE PHASE 380V 60Hz 0.21 90 - 1600 338 260
60 THREE PHASE 220V 50Hz 0.53 90 - 1300 600 460
THREE PHASE 380V 60Hz 0.32 90 - 1600 490 375
120 THREE PHASE 220V 50Hz 0.89 90 - 1300 1195 924
THREE PHASE 380V 60Hz 0.51 90 - 1600 1014 750
140 THREE PHASE 220V 50Hz 0.95 90 - 1300 1393 1078
THREE PHASE 380V 60Hz 0.48 90 - 1600 1183 875
160 THREE PHASE 220V 50Hz 1.21 90 - 1300 1590 1248
THREE PHASE 380V 60Hz 0.7 90 - 1600 1353 1005
180 THREE PHASE 220V 50Hz 1.3 90 - 1300 1790 1418
THREE PHASE 380V 60Hz 0.75 90 - 1600 1523 1135
200 THREE PHASE 220V 50Hz 1.82 90 - 1300 1990 1540
THREE PHASE 380V 60Hz 1.05 90 - 1600 1690 1250
250 THREE PHASE 220V 50Hz 1.82 90 - 1300 2110 1670
THREE PHASE 380V 60Hz 1.05 90 - 1600 1860 1380


Performance Parameter

Maximum output power
(W)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Speed range
(r/min)
Start torque
(mN·m)
Rated torque (mN·m) 1200r/min Running capacitor
6 SINGLE PHASE 110V 50Hz 0.23 90 - 1300 38 47 3μf/250V
SINGLE PHASE 220V 60Hz 0.21 90 - 1600 40 50 0.8μf/450V
15 SINGLE PHASE 110V 50Hz 0.39 90 - 1300 70 125 6μf/250V
SINGLE PHASE 220V 60Hz 0.2 90 - 1300 70 125 1.5μf/450V
25 SINGLE PHASE 110V 50Hz 0.53 90 - 1300 145 170 8μf/250V
SINGLE PHASE 220V 60Hz 0.25 90 - 1300 145 205 2μf/450V
40 SINGLE PHASE 110V 50Hz 0.79 90 - 1300 235 300 12μf/250V
SINGLE PHASE 220V 60Hz 0.4 90 - 1300 235 320 3μf/450V
60 SINGLE PHASE 110V 50Hz 1.26 90 - 1300 350 490 12μf/250V
SINGLE PHASE 220V 60Hz 0.62 90 - 1300 350 490 4μf/450V
120 SINGLE PHASE 110V 50Hz 2.04 90 - 1300 720 840 24μf/250V
SINGLE PHASE 220V 60Hz 1.02 90 - 1300 720 840 6μf/450V
140 SINGLE PHASE 110V 50Hz 2.26 90 - 1300 840 1050 28μf/250V
SINGLE PHASE 220V 60Hz 1.13 90 - 1300 840 1050 8μf/45
160 SINGLE PHASE 110V 50Hz 2.6 90 - 1300 900 1250 28μf/250V
SINGLE PHASE 220V 60Hz 1.3 90 - 1300 900 1250 8μf/450V
180 SINGLE PHASE 110V 50Hz 3 90 - 1300 1050 1450 32μf/250V
SINGLE PHASE 220V 60Hz 1.5 90 - 1300 1050 1450 10μf/450V
200 SINGLE PHASE 110V 50Hz 3.38 90 - 1300 1150 1650 32μf/250V
SINGLE PHASE 220V 60Hz 1.69 90 - 1300 1150 1650 10μf/450V
250 SINGLE PHASE 110V 50Hz 3.6 90 - 1300 1250 1850 40μf/250V
SINGLE PHASE 220V 60Hz 1.8 90 - 1300 1250 1850 12μf/450V


Performance Parameter

Running capacitor dimension (single-phase motor accessories)
Power Capacitor and Voltage Dimensions
W T H
6W 0.8μf/450V 37 11 25
3μf/250V 37 16 30
15W 1.5μf/450V 37 11 25
6μf/250V 47 18 35
25W 2μf/450V 37 16 30
8μf/250V 47 20 37
40W 3μf/450V 48 20 31
12μf/250V 59 27 38
60W 4μf/450V 48 20 32
16μf/250V 58 28 50
90W 5μf/450V 47 20 37
20μf/250V 59 30 50
120W 6μf/450V 47 20 37
24μf/250V 59 30 50
140W 8μf/450V 47 23 41
32μf/250V 60 30 50
200W 10μf/450V 59 27 38
40μf/250V 70 40 55